Central Exchange Unit for 8 Doors / Subs, 4 Masters. 
  • Wiring hub for AX system using Cat-5e
  • Two 24V DC power supply input terminals
  • Rack mountable
  • Controls all functionality of AX system
  • Two BNC composite video outputs and video switching triggers
  • CO line transfer (requires Viking K-1900-5 programmable auto-dialer)
  • Programmable functionality via supplied software

Technical Specifications

  • Consumption Video: 0.62A max. Audio: 0.65A max
  • CO Line Port: RJ11 for Viking K-1900-5 programmable auto-dialer
  • Door Release: Programmable dry contact, 24V AC/ DC, 500mA – use EL-12S (use RY-24L for larger contact rating)
  • Mounting: 19″ EIA rack (2U) or wall mount
  • Wire Type: Between Door / Sub Station, Master Station, and Central Exchange Unit: Cat-5e. Power Supply to Central Exchange Unit and Add-On Central Exchange Unit: 2-cond., overall shield – use Aiphone 821802
  • Wire Distance: Door / Sub Station to Central Exchange Unit and Add-On Central Exchange Unit: 980′. Central Exchange Unit to Master: 980′. Central Exchange Unit to Add-On Central Exchange Unit: 16′. Power Supply to Central Exchange Unit and Add-On Central Exchange Unit: 16′(22AWG) 33′(18AWG)
Aiphone AX084C intercoms installed and supported

Need a security solution?

We’re happy to help, whether you’re already a Tiger Security customer, or a new one looking for advice. We also provide free quotes, and free appraisals of existing security systems.

Book an alarm technician

Auckland area only.